{"id":1757,"date":"2021-08-24T09:32:29","date_gmt":"2021-08-24T09:32:29","guid":{"rendered":"https:\/\/fr4material.com\/?p=1757"},"modified":"2021-08-25T04:13:42","modified_gmt":"2021-08-25T04:13:42","slug":"porosity-testing-of-gold-electrodeposited-on-a-nic","status":"publish","type":"post","link":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/","title":{"rendered":"Porosity Testing of Gold Electrodeposited on a Nic"},"content":{"rendered":"<p>Substrate Electrographic Method<\/p>\n<p>1 Scope<\/p>\n<p>This test method provides a procedure for testing the porosity of gold electroplated from an alkaline (cyanide), acid, or neutral gold plating solution on a nickel substrate in contact with the gold deposit.<\/p>\n<p>2 Applicable Documents :None<\/p>\n<p>3 Materials and Equipment<\/p>\n<p>3.1 Materials :Acetone, Sodium Nitrate, Reagent GD. (NaNO3), Sodium Carbonate, Anhydrous, Reagent GD. (Na2CO3), Dimethylglyoxime, Denatured Ethyl Alcohol No. 3A, Reagent GD. (C2H5OH),  hotographic Paper with Silver Halide removed. (Kodabromide, glossy finish, single wt. pho\ua880tographic paper (fixed before use), Ammonium Hydroxide, Reagent GD. (NH4OH) <\/p>\n<p>3.2 Equipment <\/p>\n<p>3.2.1 DC power supply to 0 amp to 1 amp. DC minimum, 0 volts to 10 volts<br \/>\n3.2.2 DC Milliammeter, 0 mA to 100 mA<br \/>\n3.2.3 Electrographic Clamp-Press<\/p>\n<p>4 Equipment\/Apparatus :None<\/p>\n<p>5 Procedure<\/p>\n<p>5.1 Solution Make Up<\/p>\n<p>5.1.1 Electrolyte :Concentration: NaNO3 1% (wt.) Na2CO3, Anhydr. 4% (wt.) Distilled water \u2013 balance by wt. Preparation of 500 g (Vol. of 485 \u00b1 10 ml.) of solution<\/p>\n<p>5.1.1.1 Obtain the tare weight of 600-ml glass beaker.<\/p>\n<p>5.1.1.2 Add 400 ml of distilled water to beaker.<\/p>\n<p>5.1.1.3 Using agitation and, if necessary, heating to 48.9\u00b0C, dissolve the following in the water: Sodium nitrate\u20135g Sodium carbonate \u2013 20 g<\/p>\n<p>5.1.1.4 After salts are dissolved, add distilled water until the net weight of the solution is 500 g.<\/p>\n<p>5.1.1.5 Cool the solution to room temperature before use. 5.2 Indicator Solution The solution is a concentration of dimethylglyoxime \u2013 1% (wt.) denatured ethyl alcohol No. 3A \u2013 Balance. Perform the preparation of 300 g (vol. of 380 \u00b1 10 ml.) of solution as explained in <\/p>\n<p>5.2.1 through<\/p>\n<p>5.2.1 Obtain the tare weight of 400-ml glass beaker.<\/p>\n<p>5.2.2 Add 275 ml denatured ethyl alcohol to the beaker.<\/p>\n<p>5.2.3 Using agitation only (do not heat), dissolve 3 g of dim\ua880ethylglyoxime in the alcohol.<\/p>\n<p>5.2.4 After all additions are dissolved, add denatured ethyl alcohol until the net weight of the solution is 300 g.<\/p>\n<p>5.3 Electrographic Test<\/p>\n<p>5.3.1 Cleaning Procedure<\/p>\n<p>5.3.1.1 Using a cloth, wash the contact area with alconox solution.<\/p>\n<p>5.3.1.2 Rinse the contact area in tap water.<\/p>\n<p>5.3.1.3 Rinse the contact area in deionized water.<\/p>\n<p>5.3.1.4 Rinse the contact area with acetone and air dry.<\/p>\n<p>5.4 Cut a piece of silver halide-free photographic paper to a size slightly larger than the area of the sample or part of the sample being tested. The dimensions of the photographic paper should not exceed the dimension of that part of the sample being porosity tested by more than 0.79375 mm in any one direction.<\/p>\n<p>5.5 Wet the photographic paper, cut in 5.2 with the electro\ua880lyte solution prepared in  5.1.1. The photographic paper is immersed for 30 minutes or more in the electrolyte. The Institute for Interconnecting and Packaging Electronic Circuits 2215 Sanders Road \u2022 Northbrook, IL 60062-6135<\/p>\n<p>I<\/p>\n<p>After saturating the photographic paper with electrolyte, press the paper between two paper towels to ensure any excess electrolyte is removed from the photographic paper.<\/p>\n<p>5.6 Assemble the sample being tested for porosity and the photographic paper of 5.5 in the electrographic clamp-press as explained in 5.6.1 through 5.6.6.<\/p>\n<p>5.6.1 Place a piece of Teflon or equivalent insulating mate\ua880rial on the platform of the compression spring and piston device on the clamp-press.<\/p>\n<p>5.6.2 Place the back of the sample or area of sample being tested on top of and in contact with the Teflon.<\/p>\n<p>5.6.3 Place the silver halide-free photographic paper satu\ua880rated with electrolyte in 5.5 on top of and in contact with the face of the sample or area of the sample being tested. The emulsion side of the paper should be in contact with the test sample.<\/p>\n<p>5.6.4 Place a piece of pure gold or gold-clad copper on top of the photographic paper so the gold surface is in contact with the photographic paper. The gold or gold-clad material placed on the photographic paper is to have the same maximum dimensions as that part of the sample being porosity tested. The minimum dimensions of the gold or gold-clad material is to be not more than 0.79375 mm shorter than the dimensions of the area being tested in any one direction. Attach a lead wire to the gold or gold-clad material in order to make electrical contact.<\/p>\n<p>5.6.5 Place a piece of Teflon or equivalent insulating mate\ua880rial on the back of the gold or gold-clad material.<\/p>\n<p>5.6.6 Lower the screw of the clamping and screw the device until the pressure end of the screw is just in contact with the back of the Teflon and holds the assembly in place. Do not apply force at this time. See 5.11 for a schematic dia\ua880gram of assembly.<\/p>\n<p>5.7 Compress the spring of the clamp-press by tightening the screw device until a pressure is exerted on the assembly as in 5.6.6.<\/p>\n<p>5.8 Connect a DC power source so the positive (+) voltage contacts the sample being tested and the negative (-) voltage is connected to the lead of the gold or gold-clad material of 5.6.6. Apply a current, such that the current density is 250 mA \u00b1 50 mA per square inch of surface in contact with the pho\ua880tographic paper. Applied voltage should not exceed 10 volts. If the current density of 250 \u00b1 50 mA\/sq. in. cannot be obtained at \u226410 volts, then the time of current flow should be increased while holding the potential at 10 volts. The increased time of current flow<br \/>\ncan be calculated by the follow\ua880ing formula. Time of current flow (sec) = 250 mA\/sq. in. of surface in contact with paper Current density in mA\/sq. in. at 10 volts x 60 sec The time of the current flow should be 60 \u00b1 1 sec. <\/p>\n<p>5.9 Unclamp the assembly and remove the silver halide-free photographic paper.<\/p>\n<p>5.10 Apply one to two drops of the indiicator solution from 5.2. to the photographic paper.<\/p>\n<p>5.11 Develop the photographic paper containing indicator solution by holding the paper over an ammonium hydroxide solution.<\/p>\n<p>5.12 Dry the photographic paper to which indicator solution was added and read the test results.<\/p>\n<p>5.13 Observe the porosity test schematic, as shown in Fig\ua880ure 1.<\/p>\n<p>5.14 Test Results<\/p>\n<p>5.15 Nickel exposure through the gold will show up on the indicating photographic paper as a red stain. Copper expo\ua880sure will show up as green stains. This exposure is caused by pores, cracking, or unplated areas. These stains should be examined under 10X min, 15X max. 5.15.1 Pores Pores will show up as fine dots.<\/p>\n<p>5.15.2 Cracking Cracks will show up as continuous fine lines.<\/p>\n<p>5.15.3 Unplated Areas Unplated areas will show up as large blots or red lines.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png\" alt=\"post01\" width=\"1087\" height=\"415\" class=\"alignnone size-full wp-image-1761\" srcset=\"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01-200x76.png 200w, https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01-300x115.png 300w, https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01-400x153.png 400w, https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01-600x229.png 600w, https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01-768x293.png 768w, https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01-800x305.png 800w, https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01-1024x391.png 1024w, https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png 1087w\" sizes=\"(max-width: 1087px) 100vw, 1087px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Substrate Electrographic Method 1 Scope This test method provides a procedure for testing the porosity of gold electroplated from an alkaline (cyanide), acid, or neutral gold plating solution on a nickel substrate in contact with the gold deposit. 2 Applicable [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1757","post","type-post","status-publish","format-standard","hentry","category-knowledge"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Porosity Testing of Gold Electrodeposited on a Nic - FR4 Material<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Porosity Testing of Gold Electrodeposited on a Nic - FR4 Material\" \/>\n<meta property=\"og:description\" content=\"Substrate Electrographic Method 1 Scope This test method provides a procedure for testing the porosity of gold electroplated from an alkaline (cyanide), acid, or neutral gold plating solution on a nickel substrate in contact with the gold deposit. 2 Applicable [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/\" \/>\n<meta property=\"og:site_name\" content=\"FR4 Material\" \/>\n<meta property=\"article:published_time\" content=\"2021-08-24T09:32:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-08-25T04:13:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png\" \/>\n<meta name=\"author\" content=\"Fr4\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Fr4\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/\"},\"author\":{\"name\":\"Fr4\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/#\\\/schema\\\/person\\\/242a845619a07eb8b65f413f3eeb472b\"},\"headline\":\"Porosity Testing of Gold Electrodeposited on a Nic\",\"datePublished\":\"2021-08-24T09:32:29+00:00\",\"dateModified\":\"2021-08-25T04:13:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/\"},\"wordCount\":1010,\"publisher\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/fr4material.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/post01.png\",\"articleSection\":[\"Knowledge\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/\",\"url\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/\",\"name\":\"Porosity Testing of Gold Electrodeposited on a Nic - FR4 Material\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/fr4material.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/post01.png\",\"datePublished\":\"2021-08-24T09:32:29+00:00\",\"dateModified\":\"2021-08-25T04:13:42+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/#primaryimage\",\"url\":\"https:\\\/\\\/fr4material.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/post01.png\",\"contentUrl\":\"https:\\\/\\\/fr4material.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/post01.png\",\"width\":1087,\"height\":415,\"caption\":\"post01\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/index.php\\\/porosity-testing-of-gold-electrodeposited-on-a-nic\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fr4material.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Porosity Testing of Gold Electrodeposited on a Nic\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/#website\",\"url\":\"https:\\\/\\\/fr4material.com\\\/\",\"name\":\"FR4 Material\",\"description\":\"Professional FR4 Material Manufacturer\",\"publisher\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/#organization\"},\"alternateName\":\"Professional FR4 G10 G11 Material Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/fr4material.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/#organization\",\"name\":\"FR4 Material\",\"alternateName\":\"Professional FR4 G10 G11 Material Manufacturer\",\"url\":\"https:\\\/\\\/fr4material.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/fr4material.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/logo-7.png\",\"contentUrl\":\"https:\\\/\\\/fr4material.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/logo-7.png\",\"width\":696,\"height\":696,\"caption\":\"FR4 Material\"},\"image\":{\"@id\":\"https:\\\/\\\/fr4material.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fr4material.com\\\/#\\\/schema\\\/person\\\/242a845619a07eb8b65f413f3eeb472b\",\"name\":\"Fr4\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64a2977002025292afa6b7bcfc92bb565dfee59cf40c5b36140b9dcd37c6e9d4?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64a2977002025292afa6b7bcfc92bb565dfee59cf40c5b36140b9dcd37c6e9d4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64a2977002025292afa6b7bcfc92bb565dfee59cf40c5b36140b9dcd37c6e9d4?s=96&d=mm&r=g\",\"caption\":\"Fr4\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Porosity Testing of Gold Electrodeposited on a Nic - FR4 Material","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/","og_locale":"en_US","og_type":"article","og_title":"Porosity Testing of Gold Electrodeposited on a Nic - FR4 Material","og_description":"Substrate Electrographic Method 1 Scope This test method provides a procedure for testing the porosity of gold electroplated from an alkaline (cyanide), acid, or neutral gold plating solution on a nickel substrate in contact with the gold deposit. 2 Applicable [&hellip;]","og_url":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/","og_site_name":"FR4 Material","article_published_time":"2021-08-24T09:32:29+00:00","article_modified_time":"2021-08-25T04:13:42+00:00","og_image":[{"url":"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png","type":"","width":"","height":""}],"author":"Fr4","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Fr4","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/#article","isPartOf":{"@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/"},"author":{"name":"Fr4","@id":"https:\/\/fr4material.com\/#\/schema\/person\/242a845619a07eb8b65f413f3eeb472b"},"headline":"Porosity Testing of Gold Electrodeposited on a Nic","datePublished":"2021-08-24T09:32:29+00:00","dateModified":"2021-08-25T04:13:42+00:00","mainEntityOfPage":{"@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/"},"wordCount":1010,"publisher":{"@id":"https:\/\/fr4material.com\/#organization"},"image":{"@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/#primaryimage"},"thumbnailUrl":"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png","articleSection":["Knowledge"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/","url":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/","name":"Porosity Testing of Gold Electrodeposited on a Nic - FR4 Material","isPartOf":{"@id":"https:\/\/fr4material.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/#primaryimage"},"image":{"@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/#primaryimage"},"thumbnailUrl":"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png","datePublished":"2021-08-24T09:32:29+00:00","dateModified":"2021-08-25T04:13:42+00:00","breadcrumb":{"@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/#primaryimage","url":"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png","contentUrl":"https:\/\/fr4material.com\/wp-content\/uploads\/2021\/08\/post01.png","width":1087,"height":415,"caption":"post01"},{"@type":"BreadcrumbList","@id":"https:\/\/fr4material.com\/index.php\/porosity-testing-of-gold-electrodeposited-on-a-nic\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/fr4material.com\/"},{"@type":"ListItem","position":2,"name":"Porosity Testing of Gold Electrodeposited on a Nic"}]},{"@type":"WebSite","@id":"https:\/\/fr4material.com\/#website","url":"https:\/\/fr4material.com\/","name":"FR4 Material","description":"Professional FR4 Material Manufacturer","publisher":{"@id":"https:\/\/fr4material.com\/#organization"},"alternateName":"Professional FR4 G10 G11 Material Manufacturer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/fr4material.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/fr4material.com\/#organization","name":"FR4 Material","alternateName":"Professional FR4 G10 G11 Material Manufacturer","url":"https:\/\/fr4material.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/fr4material.com\/#\/schema\/logo\/image\/","url":"https:\/\/fr4material.com\/wp-content\/uploads\/2023\/07\/logo-7.png","contentUrl":"https:\/\/fr4material.com\/wp-content\/uploads\/2023\/07\/logo-7.png","width":696,"height":696,"caption":"FR4 Material"},"image":{"@id":"https:\/\/fr4material.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/fr4material.com\/#\/schema\/person\/242a845619a07eb8b65f413f3eeb472b","name":"Fr4","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/64a2977002025292afa6b7bcfc92bb565dfee59cf40c5b36140b9dcd37c6e9d4?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/64a2977002025292afa6b7bcfc92bb565dfee59cf40c5b36140b9dcd37c6e9d4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/64a2977002025292afa6b7bcfc92bb565dfee59cf40c5b36140b9dcd37c6e9d4?s=96&d=mm&r=g","caption":"Fr4"}}]}},"_links":{"self":[{"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/posts\/1757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/comments?post=1757"}],"version-history":[{"count":0,"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/posts\/1757\/revisions"}],"wp:attachment":[{"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/media?parent=1757"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/categories?post=1757"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fr4material.com\/index.php\/wp-json\/wp\/v2\/tags?post=1757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}